Size
|
25.4 mm x 58.4 mm x 81.3
mm (1" x 2.3" x 3.2") |
|
Weight
|
74 g (2.6 oz) |
|
Case Material
|
Cycoloy® (GE Plastics)
C120 ABS + Polycarbonate |
|
Operating Limits
|
-40 to 70°C (-40 to
158°F) and 0 to 100% RH (non-condensing) |
|
Clock Accuracy
|
+/- 2 seconds per day |
|
Battery
|
3.6 volt Lithium, 1 Amp-Hour |
|
Battery Life
|
5 years under normal use
(factory replaceable) |
|
Memory Size
|
64 KB (32,640 readings
per channel) |
|
Sampling Methods
|
First-in First-out, Stop
When Full, Delay Start, or Spot &
Average |
|
Sampling Intervals
|
User selectable from 8
seconds to 34 minutes; readings stored
to memory can be spot or averaged over
the sample interval (except for the
8 second interval) |
|
Resolution
|
8-bit (1 part in 256) |
|
PC Requirements
|
Windows PC with one free
serial or USB port depending on connection |
|
Software Requirements
|
TrendReader® Express
- compatible with Windows 2000,
XP or Vista 32bit. Also compatible
with TrendReader® 2 (Optional) |
|
Temperature Sensor
Type
|
CMOSens® (by Sensiron) |
|
Temperature Sensor
Range
|
-40 to 70°C (-40 to
158°F) |
|
Temperature Sensor
Accuracy
|
+/- 0.6°C @ 25°C
(+/- 1.0°F @ 77°F); +/- 2.0°C
from -40 to 70°C (+/- 3.6°F
from -40 to 158°F) |
|
RH Sensor Type
|
CMOSens® (by Sensiron) |
|
RH Sensor Range
|
0 to 100% RH (non-condensing) |
|
RH Sensor Accuracy
|
+/- 4% RH between 20 and
80% RH; otherwise +/- 5% |
|
Calibration
|
Factory calibration verification
and NIST certificates are available
upon special request. |