Chemical,Oxygen,Demand,COD,PCcompact,vario,Photometer

Chemical Oxygen Demand
(COD) PCcompact vario Photometer


Chemical Oxygen Demand (COD) PCcompact vario Photometer

PCcompact COD vario Package

COD (Chemical Oxygen Demand) is an important parameter in the assessment of waste water quality. The PCcompact COD vario package allows accurate and simple determination of COD. It includes the PCcompact COD vario photometer, two sets of tube tests for the range 0-150 mg/l and 0-1500 mg/l, the COD-Reactor AL 32 and a stand for tubes.

COD Reactors AL 32 and AL 34

With the Reactor AL 32 up to 8 standard 16 mm diameter tubes can be digested at the same time and the unit has additional space for a 22 mm digestion tube. The Reactor AL 34 has space for fourteen standard 16 mm tubes and two 22 mm digestion tubes. Both reactors include 2 temperature settings: 148¡C and 100¡C. The digestion time is set using the keypad on the front of the reactor. The reactor automatically switches off after the predetermined digestion time and an audible alarm will alert the operator that the digestion is complete.

PCcompact COD vario

The Aqualytic Photometer PCcompact COD vario covers a measuring range from 0 to 15000 mg/l O2 . It is therefore suitable for all areas of waste water analysis. Two stable LED light sources, a water-proof sample chamber, the large display and keypad all help to guarantee reliable and user-friendly operation.

COD-tube test

Aqualytic tube tests allow precise and accurate water analysis with the minimum of effort. Just add a specified volume of sample to the vial, place it in the COD reactor for chemical digestion, then transfer to the photometer for COD measurement. COD-tube tests are available in three measuring ranges: 0 - 150 mg/l O2 , 0 - 1500 mg/l O2 , 0 - 15000 mg/l O2 . The round tubes are made of special optical glass; they are supplied as packs of 25 reaction tubes in a secure storage and dispatch box. A standard chemical composition and 16 mm tube diameter means that Aqualytic COD-tube tests can be used in other brands of photometers.

Measurement cycle:

3 seconds depending on method

Display:

LCD-display

Optics:

temperature-compensated LED(s) and photo-sensor amplifier in water protected sample chamber

Sample chamber:

waterproof

Ranges:

0 - 150 mg/l O2 (± 3.5 %*)
0 - 1500 mg/l O2 (± 3.5 %*)
0 - 15000 mg/l O2 (± 3.5 %*)
* based on the use of potassium-hydrogene phthalate standards (DIN 38 409)

Keypad:

3 key polycarbonate film, splash proof

Power supply:

9 V powerpack battery providing 40 hours operation - equivalent to approx. 600 measurements with a cycle of 4 minutes

Auto - OFF:

automatic switch-off approx. 5 minutes after last keypress

Housing:

ABS

Dimensions:

190 x 110 x 55 mm (W x D x H)

Weight:

approx. 0,4 kg (basic unit)

Environmental conditions:

temperature: 0 ö 40 ¡C
rel. humidity: 30 ö 90% rel. (non-condensing)

CE-conformity:

DIN EN 50081-1
VDE 0839 Teil 81-1: 1993-03
DIN EN 50082-2
VDE 0839 Teil 82-2: 1996-02

Catalogue-Numbers

Cat.-No.

Item

4209240

PCcompact COD vario Package

4209250

PCcompact COD vario (basic unit)

418930

COD-Reactor AL 32

418934

COD-Reactor AL 34

 

COD-tube tests

420720

Range 0 - 150 mg/l O2

420721

Range 0 - 1500 mg/l O2

420722

Range 0 - 15000 mg/l O2

Chemical Oxygen Demand
(COD) PCcompact vario
Photometer