SPECIFICATIONS
|
| Range: |
Auto Ranging, 0-100 %T Transmission |
| Resolution: |
±1.0% of Reading |
| Accuracy: |
±1% of Full Scale |
| Wavelength: |
Ultra Violet 253.7nm |
| Response Time: |
Reading is Updated every 30 seconds |
| Operating Temperature: |
-4°F (-20°C) to 122°F (50°C) |
| Storage Temperature: |
-4°F (-20°C) to 140°F (60°C) |
| Optical Cleaning: |
Removable Cuvette plus Inline Cleaning Solution Connection |
| Flow Rate: |
140-180ml / min |
| Analyzer Separation: |
Up to 1000ft (300m) |
| Communication: |
RS-485 Serial Port, 9600 Baud, Isolated 1.5kv |
| Sensor/Sampler Enclosure: |
Stainless Steel |
| Analyzer Case Dimensions: |
330 x 290 x 200mm (13" x 11.5" x 8") |
| Calibration: |
Automatic, w/Calibration periods User Selectable |
| Keyboard Entry Analyzer: |
8 Membrane Function Keys |
| Built In Diagnostics: |
Yes |
| Analog Output: |
4-20 mA and .1, 1 or 10 Vdc |
| Alarms: |
1 System / Two Settable Hi, Lo or Off with 2.5. 5.0 or 10% Settable Deadband |
| Alarm Contact Rating: |
Max. 250
VAC @ 5.0A Resistive, Isolated, Form C (SPDT) |
| Certification: |
CE, ETL (UL), ETLC (CSA), NEMA 4X,IP66 |
|
|
STANDARD FEATURES:
Graphical Display:
Quickly view historical trending of %T readings over an 8 or 24 hour period.
All Weather Enclosure:
Enclosure and Sample Lines are heated and insulated for outdoor installations.
Automatic Calibration:
Automatic Calibration ensures accuracy and repeatability over the full measuring range.
On Screen Instructions:
Easy to use menus guide you through set-up and calibration procedures.
Three Separate Alarm Contacts:
System alarm and two user programmable HI/Lo alarms provide continuous confidence in the measuring process.
Made in the USA
|
|
|
Catalog Number
|
Description |
|
|
Instruments - Single Enclosure |
|
19566
|
Micro T UV Complete On-Line Analyzer with Enclosure, 115 Volt |
|
19565
|
Micro T UV Complete On-Line Analyzer with Enclosure, 240 Volt |
|
|
Note: Both of above include a stainless steel enclosure with a window for viewing the analyzer. |
|
|
Instruments - Modular Enclosure |
|
19570
|
Micro T UV Sensor / Sampler with Enclosure, 115 Volt |
|
19569
|
Micro T UV Sensor / Sampler with Enclosure, 240 Volt |
|
19568
|
Analyzer for Micro T UV (Use with catalog # 19570, 19569.) 115/240 Volt |
|
19567
|
Enclosure for Analyzer (Use with catalog # 19568.) |
|
|
Accessories |
|
19306
|
100%T Standard Solution (4 x 1 gallon) |
|
19402
|
Cleaning and De-scaling Solution (4 x 1 gallon) |
|
22965
|
Cleaning Kit (Includes modified Cap, Tubing and Connectors.) |
|
20815
|
Interconnect Cable between the analyzer and the Sensor / Sampler (Use with catalog # 19568.) |
|
|
|
|
20519
|
RS-485 Module, Isolated (Analyzer) |
|
21555
|
Desiccant Tray |
|
22974
|
Cuvette, Quartz (Online) |
|
22041
|
Pump Head Kit |
|
22047
|
Pump Tubing Kit |
|
22811
|
Source Tubing Assembly with Strainer (25 feet of Tubing) |
|
|
|
|
19560
|
Micro T UV Enclosure Upgrade for catalog # 19565 or 19566
(Upgrade from 304 to 316 stainless steel.) |
|
19561
|
Micro T UV Enclosure Upgrade for catalog # 19569 or 19570
(Upgrade from 304 to 316 stainless steel.) |
|
20106
|
Stilling / Bubble Chamber
(Recommended for use with all drinking water applications.) |