ph,ORP,Conductivity,Humidity,Turbidity,Measuring,Instruments

ph, ORP, Conductivity Humidity Measuring, Turbidity Measuring Instruments

pH, ORP, Conductivity

Liquid Filled pH Combined Electrode, APS-X2Q
EXPERT-LINE
Measuring range: pH 1 up to 12
Connection: Pg 13,5
Suitable for low conductivities above 1 µS/cm
temperature range: -15 up to 80°C
Salt: KCl-liquid fill
Diaphragm: ceramic
Temperature sensor: Pt 100 possible
Download Brochure

Gel-filled pH-Combined Electrode APS-X1Q
EXPERT-LINE
Measuring range: pH 1 up to 12
Connection: Pg 13,5
temperature range: -15 up to +80°C
Pressure rating: up to 6 bar
Salt: KCl gel filling
Diaphragm: PTFE (teflon), ring form
Temperature sensor: Pt 100 possible
Download Brochure
ph,ORP,Conductivity,Humidity,Turbidity,Measuring,Instruments Gel-filled pH-Combined Electrode APS-Z
COMPACT-LINE
Measuring range: pH 0 up to 12
Connection: Pg 13,5
temperature range: -5°C up to +80°C
Pressure rating: up to 10 bar
Salt: KCl gel filling
Diaphragm: ceramic or (PTFE)- ring
Temperature sensor: Pt 100 possible
Download Brochure

Gel Filled Combined Electrode, ARS-X1Q
EXPERT-LINE
Active section: platinum ring or gold pin
Connection: Pg 13,5
temperature range: -15 up to +130°C
Pressure rating: up to 6 bar
salt: KCl gel filling
Diaphragm: PTFE (teflon), ring form
Download Brochure

Gel Filled ORP Electrode, ARS-Z
COMPACT-LINE
Sctive section: platinum or gold
Connection: Pg 13,5
temperature range: -10°C up to +90°C
Pressure rating: up to 10 bar
Salt: KCl gel filling
Diaphragm: ceramic or (PTFE)- ring
Salt bridge for longer life time
Download Brochure
ph,ORP,Conductivity,Humidity,Turbidity,Measuring,Instruments Inductive Conductivity Measuring Cell ACS-X0I
EXPERT-LINE
Measuring range: 5 µS/cm up to 2000 mS/cm
Connection: G3/4" of 1.4571 or 1"NPT of PEEK
Material of sensor: PEEK (resistant to chemical attack)
temperature range: -20 up to +130°C
Pressure rating: up to 16 bar
Cable: 5 meters fixed cable
Temperature sensor: coated Pt 100 integrated
Download Brochure

Inductive Conductivity Measuring System, ACI-Z
COMPACT-LINE
Measuring range: up to 1000 mS/cm
Connection: pipe connection DN 50 made of st. st.
Material of sensor: PVDF, for most difficult media
temperature range: up to 120°C (short-time up to 140°C)
Pressure rating: up to 10 bar
2 analoge current outputs for conductivity and
temperature
Temperature sensor: Pt 100 is integrated
Download Brochure

Conductive Conductivity Measuring Cells, ACS-X
EXPERT-LINE
Measuring range 1, K=0,01: 0,04 ... 20 µS/cm
Measuring range 2, K=0,1: 0,1 ... 200 µS/cm
Measuring range 3, K=1,0: 50 ... 500 µS/cm
Measuring range 4, K= 1,0: 10 µS/cm ... 20 mS/cm
Connection: NPT 1/2 " or G1"
Electrode Material: st. st. 1.4571 or. graphite
Temperature sensor: Pt 100 possible
Download Brochure
ph,ORP,Conductivity,Humidity,Turbidity,Measuring,Instruments Conductive Conductivity Measuring Cells, ACS-Z
COMPACT-LINE
Measuring range 1, K=0,01: 0,05 ... 10 µS/cm
Measuring range 2, K=0,1: 0,5 ... 5000 µS/cm
Measuring range 3, K=1,0: 5 µS/cm ... 100 mS/cm
Connection: thread G 3/4 A
Electrode Material: st. st. 1.4571 bzw. graphite
temperature range: up to 135°C
Pressure rating: up to 16 bar
Temperature sensor: Pt 100 integrated
Download Brochure

Transmitters for pH-Value and ORP, APM-X
EXPERT-LINE
Measuring range: pH: 0 up to 14 pH
Redox: -1500 up to +1500
With panel mounted housing or field mounted housing
Large text LC-Display
analogue actual-value output scaleable
Alarm relays
Two additional relays for use as control contacts two digital inputs
Download Brochure

Transmitters for pH-value APM-Z
COMPACT-LINE
Measuring range: pH -1 up to 14
With panel mounted housing or field mounted housing
Display of pH-value and temperature with LEDs
analogue actual-value output scaleable
2 relays for control functions (PID) programmable
2 binary inputs
1 binary output (alarm contact or temperature limit contact
Download Brochure
ph,ORP,Conductivity,Humidity,Turbidity,Measuring,Instruments Transmitter for ORP, ARM-Z
COMPACT-LINE
Measuring range: -1999 up to +1999 mV
Withpanel mounted housing or field mounted housing
Display of ORP and temperature with LEDs
analogue actual-value output scaleable
2 relays for control functions (PID) programmable
2 binary inputs
1 binary output (alarm contact or temperature limit contact)
Download Brochure

Transmitter for Specific Conductivity, ACM-X
EXPERT-LINE
Measuring range: conductivity: 0 ... 2000 mS/cm
resistance: 0 ... 86 M Ohm cm
With panel mounted housing or field mounted housing
Large LC-Display for text
Analogue actual-value output scaleable
Alarm relays
Two additional relays for use as control contacts
Two digital inputs
Download Brochure

Transmitter for Specific Conductivity, ACM-Z
COMPACT-LINE
0 up to 200 mS/cm
With panel mount housing or field mounting housing
Display of conductivity and temperature with LEDs
analogue actual-value output scaleable
2 relays for control functions (PID) programmable
2 binary inputs
1 binary output (alarm contact or temperature limit contact)
Download Brochure

pH Electrode with Plastic Sheathing, APS-X5K
EXPERT-LINE
Measuring range: pH 0 up to 11
Connection: NPT 3/4"
Shock-proof because of plastic case
Temperature range: 0 up to 80°C
Pressure rating: up to 7 bar
Diaphragm: PTFE (teflon)
Temperature sensor: Pt 100 possible
Cable: 5 m fixed cable
Download Brochure

ORP Electrode with Plastic Sheathing, ARS-X5K
EXPERT-LINE
Active section: platinum -ring
Connection: NPT 3/4"
Shock-proof because of plastic case
temperature range: 0 up to 80°C
Pressure rating: up to 7 bar
Diaphragm: PTFE (teflon)
Cable: 5 meters fixed cable
Download Brochure

Accessories for Analysing Devices
Immersion assemblies
Flow assemblies
Process assemblies
Buffer solutions for pH and ORP
Calibration solutions for conductivity
temperature sensors
Wall mounting set for field housing
Pipe mounting set for field housing
Download Brochure

Humidity Measurement Instruments
ph,ORP,Conductivity,Humidity,Turbidity,Measuring,Instruments Humidity/temperature Measuring Instrument (hygrometric method) AFH-G
Operating temperature: -30...+80 °C
umidity: 30..100 % RH
Probe: polymer fibre inside st. st. housing, 220 mm
Max. pressure: pressureless
Max. temperature: -20...60 °C (housing),
-40..+80 °C (sensor)
Accuracy of temperature: ±0, 5 °C
humidity: ± 2,5 % RH (>40% RH: ± 3,5 % RH)
Output: temperature: Pt100 or 4-20 mA
humidity: 100-138,5 Ohm or 4-20 mA
Download Brochure
ph,ORP,Conductivity,Humidity,Turbidity,Measuring,Instruments Humidity/ Temperature Measuring Instrument (capacitive) AFK-G
Operating range: temperature: -60...+200 °C
humidity: 0... 100 % RH
Max. pressure: 25 bar
Max. temperature: +200 °C
Accuracy of temperature: ±0,1 °C
humidity: ± 2 %RH
Output: 2 x 4-20 mA
Download Brochure
ph,ORP,Conductivity,Humidity,Turbidity,Measuring,Instruments Humidity/Temperature Instrument (capacitive) AFK-E
For Industrial applications
Operating range temperature: -40...+180 °C
humidity: 0... 100 % RH
Max. pressure: 15 bar
Max. temperature: -40...60 °C (housing),
-40...+180 °C (sensor)
Accuracy of temperature: ±0, 2 °C
humidity: ± 2 % RH (0..90% RH)
Output: 0-5 V, 0-10V, 4-20 mA
Dew-point temperature, Freezing point temperature, abs. humidity, specific enthalpy,
Water-vapuor partial pressure, mixing ratio
Download Brochure
ph,ORP,Conductivity,Humidity,Turbidity,Measuring,Instruments Humidity Measuring Instrument with Indicator (capacitive) AFA-G
Operating range: 0 - 100 % RH
Max. pressure: pressureless
Max. temperature: 0...60 °C
Accuracy : ± 2 % RH (5...95 % RH)
output: 4-20 mA
Plug-on display: 3,5-digit LED
Option: limit switch
Download Brochure
ph,ORP,Conductivity,Humidity,Turbidity,Measuring,Instruments Humidity Annex Switch AFS-G3
Operating range: 50 - 100 % RH
Max. pressure: pressureless
Max. temperature: 0...60 °C
Accuracy: ± 3 %RH
Contact: 1 micro switch, adjustable from inside
Download Brochure
ph,ORP,Conductivity,Humidity,Turbidity,Measuring,Instruments Hygrostat AFS-G1
Operating range: 35 - 100 % RH
Probe: polymere fibres inside st. st. housing, 220 mm
Max. pressure: pressureless
Max. temperature: -30...60 °C
Accuracy: ± 3,5 % RH (<50%RH: ± 4 % RH)
Contact: 1 micro switch
Download Brochure
ph,ORP,Conductivity,Humidity,Turbidity,Measuring,Instruments Room Hygrostat AFS-G2
Operating range: 35 - 100 % RH
Max. pressure: pressureless
Max. temperature: 0...60 °C
Accuracy: ± 3 % RH
Contact: 1 micro switch, adjustable
Download Brochure
Turbidity Measuring Instruments
ph,ORP,Conductivity,Humidity,Turbidity,Measuring,Instruments Turbidity Meter LAT-N1
4-beam pulsed light method
Measuring range: 0,01...1000 TE/F
0,01 ... 500 EBC
Connections: DN 40, 50, 65, 80, 100
Material: st. st., PEEK
Max. pressure: 6 bar
Max. temperature: 0 ... 80°C (short-time 120°C)
Accuracy: +/- 1% FS
Output: 4...20 mA
Download Brochure
ph,ORP,Conductivity,Humidity,Turbidity,Measuring,Instruments Turbidity Meter LAT-N2
Infrared-pulsed (absorbtions-)-method
Measuring range: 0...100%
Connections: DN 40, 50, 65, 80, 100
Material: st. st.
Max. pressure: 10 bar
Max. temperature: 0...90°C (short-time 120°C)
Accuracy:
Output: 0/4...20 mA
Download Brochure

Turbidity Meter LAT-N3
Infrared-reflect scattering method
Measuring range: 0...100%
Connection: G1/2
Material: st. st., PEEK
Max. pressure: 10 bar
Max. temperature: 0...125°C
Repeatability: 1% FS
Output: 4...20 mA, switching output: acktive output
Download Brochure

ph,ORP,Conductivity,Humidity,Turbidity,Measuring,Instruments Turbidity Meter ATA-K
Absorbtion method (infrared)
Measuring range: 0...4 CU
Connections: DIN-/ ANSI-flange, NPT, BSP-thread, hygenic connection
Material: st. st.
Max. pressure: 16 bar
Max. temperature: 0...10°C (short-time 120°C)
Measuring Accuracy: +/-2% FS
Output: 4...20 mA, 2 limit switches
Download Brochure