720 Series II pH/ORP Monitor/Controllers

The advanced "isolated" circuitry of the 720 Series II pH/ORP Monitor/controllers guarantees accurate and reliable measurements completely eliminating ground-loop and noise issues. 

The unique sensor preamp allows for longer distances between the sensor and the Monitor/controller without the loss of accuracy or reliability.

All Myron L pH Monitor/controllers feature a highly refined and precise Temperature Compensation circuit.  This feature perfectly matches the NERNST equation correcting the displayed reading to 25ºC.  The TC may be disabled to conform with USP 24.

Built-in electronic calibration allows for fast quality checks without buffers.
(Note: for maximum system accuracy buffers are recommended).

A push-to-test button makes set point checks easy, while the internal alarm set discourages unauthorized adjustments.

Standard on all controller models is a heavy-duty 10 amp output relay, operating on either increasing or decreasing readings.  Bright green/red LED's indicate above/below set point readings.

All 720 Series II models feature a IPA64/NEMA 3 splash & corrosion-proof rated enclosure.  Compact in size, 6 x 4.8 inches (152 x 122mm), the 720 Series II models are suitable for panel, bench or surface mounting.

Accessories include a Remote Alarm - RA™.  Custom and OEM Models available.


Features

pH 0 - 14 or ORP ± 2000mV
Choice of analog meter or 3½ digit LCD
Advanced "Isolated" circuitry
Automatic temperature compensation to 25°C (NERNST equation)
Isolated 0-10 VDC recorder output - standard
IP64/NEMA 3X splash & corrosion proof enclosure
Built-in electronic calibration
Single setpoint/alarm standard
Adjustable setpoint hysterisis 
Solid state output
10 amp relay operates on choice of increasing or decreasing set point
Push-to-test set point check
Internal set point discourages unauthorized adjustment
Solid State 24 VDC Output
Selectable 115/230VAC
CE Approved
Unique, easily installed sensors
Heavy duty "F" model sensors may be installed in ANY direction,
including inverted

pH/ORP Monitor/controller Specifications

Ranges 0-14 pH or ± 2000mV
Display
Analog Models: 2½" (63mm) analog meter
Digital Models: 1/2" (13mm) 3½ digit LCD; opt. 3½ digit backlit LCD
Linearity Electronics: ± 0.05% (0.01 pH units / ± 1 mV of full scale)
Resolution
Analog Meter: ± 0.13 pH units / ± 40mV
Digital Display: ± 0.01 pH units / ± 1mV
Sensitivity 0.05% of full scale (0.01 pH units / 1.0mV)
Stability ± 0.05% of full scale (± 0.01 pH units / ± 1.0mV)
Repeatability ± 0.05% of full scale (± 0.01 pH units / ± 1.0mV)
Calibration Check Built in (7 & 0 pH / 0 & -2000mV)
Recorder Output Isolated 0-10 VDC @ 5 mA max. (linear); standard all models
Sensor Input 1 (3 input option available) pH & ORP sensors may NOT be mixed
Control Function
Single alarm/controller - fully adjustable 0-100% of full scale
Second alarm/controller - with above specifications, optional
Hysterisis - Adjustable from 0.3-3% of full scale
Indicators - Above (red) and below (green) setpoint LEDs (reversible)
Contact Rating - SPDT 10 amp @ 250 VAC, 30 VDC.  Relay operates with increasing or decreasing reading (user selectable)
Solid State Output Powered; 24VDC unregulated 30mA max.
Power 115/230 VAC, 50/60 Hz, ±15% (user selectable)
Maximum Power Consumption 100mA @115VAC
Dimensions 6" (152mm) H x 4.8" (122mm) W x 3.8" (96mm) D
Construction Fully gasketed heavy-duty ABS case; splash & corrosion proof IP64/NEMA 3 rated
Ambient Temperature Range 32°F to 140°F (0°C to 60°C)
Weight 2 lbs (0.9 kg)