The
choice of professionals for years, this compact instrument
has been designed specifically to demonstrate and test Point
of Use (POU) reverse osmosis or distillation systems. By measuring
electrical conductivity, it will quickly determine the parts
per million/Total Dissolved Solids (ppm/TDS) of any drinking
water.
With a single before and after test,
this handy device effectively demonstrates how your RO or
distillation system eliminates harmful dissolved solids. It
will also service test systems, including membrane evaluation
programs.
Features
- Instant and accurate TDS tests
- Electronic Internal Standard for easy field calibration
- Fast Auto Temperature Compensation
- Rugged design for years of trouble-free testing
- Simple to use
Automatic
Temperature Compensation:
Why
It Is Important
The graph below illustrates a TDS reading of
a 500 ppm water sample tested with a non-temperature compensated
conductivity meter. The same water sample appears to have
a higher level of TDS when heated (and lower TDS when chilled).
Actually, only conductivity readings change with temperature.
TDS does not change.

Many instruments ignore the importance of temperature. Others
require a separate thermometer for testing sample temperature,
then manual adjustment of the meter. All Myron L instruments,
however, feature fast and precise Automatic Temperature Compensation.
The result: a more accurate, useful instrument.
How
Conductivity Measures ppm/TDS
Total
Dissolved Solids (TDS) conduct electricity. This conductivity
allows measurement of the concentration of these salts directly
in parts per million (ppm). However, the salts composition
in waters can vary significantly by location. Since various
salts pass current differently, it was necessary to determine
an average ppm/ conductivity relationship. The
Myron L Company established the 442 Standard over
40 years ago. It remains the worlds most widely accepted
standard of its kind.
If
You Also Test pH
Myron L offers instruments that check both TDS
and pH, and are widely used throughout the RO industry.
- pH sensor is built-in for maximum protection
- Automatic temperature compensation
- Full calibration capability
- Many models available
Also see our RO-CHECK
POU TDS Monitor
|
Accessories
|
|
Standard Solutions are used to periodically recalibrate instruments for greatest accuracy. 442-1000 (1000 ppm/TDS) is the type used in MyronL factory calibrations.
Model: 442-1000 (Specify quart, gallon or 2 oz.)
|
|
Porta-Pak Carrying Case
For use with all Myron L DS/pDS portable instruments. Foam lined and molded of sturdy ABS plastic.
Model: PTP
|
|
|
Additional Information |
RO METERS™ Data Sheet
(includes specs, options & order info) |
click here:
PDF |
|
|