PC 2700 Benchtop Meter from Oakton Instruments

PC 2700, Benchtop Meter, Oakton InstrumentsYour all-in-one solution for multiparameter research work in the lab!

  • PC 2700 measures pH, ORP, ion, conductivity, total dissolved solids (TDS), salinity, resistivity, and temperature

  • Measures salinity from 0.0 to 80 ppt and resistivity from 2.000 ohms to 20.0 Mohms

  • Brilliant backlit display with dynamic stability indication

  • Up to 500 point memory with date-time stamp for GLP

  • Output data to printer or PC

  • Accepts either 2-cell or 4-cell electrodes

  • Features auto-standardization, auto-calibration, and autoranging

  • Calibration due alarm with password protection for setup and calibration

  • Temperature coefficient of 0.000 to 10.000%

  • Automatic or manual temperature compensation

The PC 2700 meter offers a new compact design that is over 40% smaller than other benchtop meters. The large display is easy to read even at a distance and features stability indication. All measurements include temperature display. The meter includes auto-buffer recognition for both USA and NIST pH buffer sets, automatic or manual temperature compensation, temperature in F or C, and display Hold. A calibration due alarm function means no more out-dated calibrations. The water-resistant membrane keypad offers password protection for both set-up and calibration.

Multiple pH slopes and offset display enables quick, easy electrode diagnosis. The electrode holder can be mounted on either side of the meter. The convenient pull-out, quick-reference card keeps keypad functions at your fingertips

Click below to download Acrobat (.pdf) file of:
2700 series Benchtop Meter Manual

Learn more about the Oakton 2700 series benchtop meters

Measures pH, ORP (mV/Rel. mV), conductivity, TDS, salinity, resistivity and temperature(C or F)
pHRange -2.000 to 20.000
pHResolution 0.1/0.01/0.001
pHAccuracy 0.002 + LSD
pHCalibration Up to 6 preset or 5 custom with autobuffer recognition of USA, DIN, NIST, User-defined, and Custom buffer sets
mVRange -2000.0 to 2000.0
mVResolution 0.1
mVAccuracy 0.2
mVCalibration Offset up to 150 mV
IonRange 0.001 to 19,999 ppm (2000 mV)
IonResolution 2 or 3 digits
IonAccuracy 0.5% full scale (monovalent) 1% full scale (divalent)
IonCalibration 2 to 8 points
ConductivityRange 0.050 uS/cm to 500.0 mS/cm
ConductivityResolution 0.01 uS/0.1 uS; 0.001 uS/ 0.01 mS/0.1 mS
ConductivityAccuracy 1% full scale
ConductivityCalibration Automatic (4 points); maximum 1 per range; manual (5 points); maximum 1 per range
TDSRange 0.050 ppm to 500 ppt @ 1.00 TDS factor
TDSResolution 0.01 ppm/0.1 ppm; 0.001 ppt/ 0.01 ppt/0.1 ppt
TDSAccuracy 1% full scale
TDSCalibration Up to 5 points
TemperatureRange 32 to 212F (0.0 to 100.0C)
TemperatureResolution 0.1F or C
TemperatureAccuracy 0.5F or 0.3C
TemperatureCalibration Offset 0.1C increments up to 5C/9F
Memory Up to 500 data sets with time-date stamping for GLP compliance
RS-232 Bi-directional RS-232; includes software
Dimensions 6 1/8" x 6 7/8" x 2 3/4" (15.5 x 17.5 x 6.9 cm)