Benchtop,Conductivity,Meter,CON 510,Oakton,Instruments

Benchtop Conductivity Meter CON 510 from Oakton Instruments

CON 510 Benchtop Conductivity Meter is an affordable way to take consistent, accurate conductivity measurements in your laboratory.

 

Benchtop,Conductivity,Meter,CON 510,Oakton,Instruments

 

Benchtop,Conductivity,Meter,CON 510,Oakton,Instruments Dual display shows both conductivity or TDS and temperature in °C or °F
Benchtop,Conductivity,Meter,CON 510,Oakton,Instruments Single-and multi-point automatic or manual calibration: customize meter calibration for quick checks or for best meter accuracy
Benchtop,Conductivity,Meter,CON 510,Oakton,Instruments Autoranging across five ranges: offers the best resolution for your measurements
Benchtop,Conductivity,Meter,CON 510,Oakton,Instruments Advanced set up mode: recalls previous calibration data, conductivity/TDS effective cell constants per range, and more
Benchtop,Conductivity,Meter,CON 510,Oakton,Instruments Built-in non-volatile memory: stores up to 50 conductivity or TDS readings with corresponding temperature
Benchtop,Conductivity,Meter,CON 510,Oakton,Instruments Automaticor manual temperature compensation
Benchtop,Conductivity,Meter,CON 510,Oakton,Instruments Selectable cell constant
Benchtop,Conductivity,Meter,CON 510,Oakton,Instruments Adjustable conductivity to TDS conversion factor and temperature coefficient: gives highest accuracy in any solution
Benchtop,Conductivity,Meter,CON 510,Oakton,Instruments Selectable normalization temperature: choose between 15°C and20°C
Benchtop,Conductivity,Meter,CON 510,Oakton,Instruments Built-inelectrode holder arm; selectable "Ready" indicator; Hold function; diagnostic error messages
Benchtop,Conductivity,Meter,CON 510,Oakton,Instruments Includes WD-35608-50 conductivity cell
Measures Conductivity,TDS, C, F
Conductivity Range 0to 19.99
0 to 199.9
0 to 1999 S
0 to 19.99 mS
0 to 199.9 mS
Conductivity Resolution 0.01S
0.1 S
1 S
0.01 mS
0.1 mS
Conductivity Accuracy 1%full scale or 1 digit
Conductivity Calibration Automatic: single or multi-point up to 4 points (84 S,1413 S, 12.88mS, 111.8 mS)
Manual: single or multi-point up to 5 points (one userselectable point per range for multi-point calibration)
TDS Range 0.00to 9.99 ppm
10.0 to 99.9 ppm
100 to 999 ppm
1.00 to 9.99 ppt
10.0 to 99.9 ppt
100 to 200 ppt
TDS Resolution 0.01ppm
0.1 ppm
1 ppm
0.01 ppt
0.1 ppt
TDS Accuracy 1% full scale or 1 digit
TDS Calibration Automatic: single or multi-point up to 4 points (84S, 1413S, 12.88mS, 111.8mS)
Manual: single or multi-point up to 5 points (one user selectable point per range for multi-point calibration)
Temperature Range 0.0to 100.0C
32 to 212.0F
Temperature Resolution 0.1Cor F
Temperature Accuracy 0.5C or 0.9F
Temperature Calibration offset 0.1 increments up to 5
Memory upto 50 sets with temp
Cellconstant selectable 0.1, 1.0, 10
Temperature coefficient adjustablefrom 0 to 10% per C or F
Dimensions 9"W x 2-3/8"H x 7"D
Shippingweight meter only 1.25 lbs. (0.6 kg); boxed 3 lbs (1.4 kg)

Back to Conductivity Benchtop Meters