Search This Site

(Search by Product Type i.e. Level or Brand Name i.e. Walchem)

MS2900L - CorrTran MV

USA Toll Free: 1-800-730-0302 Tel: 416-240-1920 - sales@metexcorporation.com

Corrosion Monitoring,Instruments,Meters

MS2900L - CorrTran MV

LPR 4-20mA / HART® Transmitter

Metal Samples' CorrTran MV transmitter measures general corrosion, localized corrosion (pitting), and conductance, and transmits that information to operators via 4 to 20mA / HART® protocol in real time. The corrosion rate or pitting factor is configured as the primary variable using a standard 2-wire 4 to 20 mA output. The remaining outputs are configured as secondary and tertiary HART variables.

The CorrTran MV utilizes state-of-the-art algorithms and data analysis techniques to accurately measure general corrosion rate and pitting. Harmonic distortion analysis (HDA) is applied to improve the performance of the industry-accepted linear polarization resistance (LPR) technique used to measure corrosion rate.

To further enhance the performance, an application-specific Stern-Geary variable (B value) is calculated and updated every measuring cycle. There is no need to manually update the B value because of process changes. During the measurement cycle, the CorrTran MV also performs an automated electrochemical noise (ECN) measurement, which in combination with the corrosion rate data can provide a measurement of localized corrosion (pitting).

The CorrTran MV works with Metal Samples three-electrode CorrTran style probes and electrodes. Probes are available in a variety of mounting types and materials to suit almost any type of installation.

Features

• On-line corrosion monitoring, multivariable
• 2-wire, 4 to 20 mA transmitter, HART interface
• General corrosion, localized corrosion (pitting), and conductance monitoring via HART
• Stern-Geary B value automatically updated for changes in the process

Technical Specifications

Model: MS2900L CorrTran MV LPR 4-20mA/HART Transmitter

Physical Data

Instrument Weight: 1.1 lb (500 g)
Instrument Dimensions: 3.78” x 3.15” x 6.30” (96mm x 80mm x 160mm)
Operating Temperature: -40° to 158°F (-40° to 70°C)
Enclosure Material: Aluminum
Degree of Protection: IP66, NEMA 4X
Electrical Entry: ¾ NPT

Electrical Data

Electrical Connection: 2-wire 4-20 mA with HART
Minimum terminal voltage: 11 V at 20 mA without alarm, or at 22.5 mA with alarm
Maximum terminal voltage: 30 V
Current Consumption: 4 to 22.5 mA
Maximum Load (at 24 V DC): 575 O with high alarm, or 650 O without high alarm

Measurement Data

Probe Type: 3-Electrode LPR
Measurement Type: General Corrosion1 Localized Corrosion Conductance
Measurement Unit: mpy (mils per year) or
mmpy (mm per year) Unitless microSiemens (µS)
Measurement Range(s): Default Range:
0 to 40 mpy
(0 to 1 mmpy) Default Range:0.0 to 1.0
Low Range: 0.0 to 0.3
High Range: 0.3 to 1.0 5 to 333,333
Maximum2: 1000 mpy
(25 mmpy)

1 Instantaneous corrosion
rate available as a primary variable. Average corrosion rate available via HART.
2 Range adjustable via
HARTor factory set.
Maximum Measured Error: Excitation voltage < 0.05% of full span
Corrosion current measurement <0.2% of full span
Factory Settings: B value (Stern Geary value): 25.6 mV
K value (corrosion constant): 11800 (2e- in reaction)
Measurement Cycle: 4 to 21 minutes (depends on configuration)

Output Data

Output Signal: 4-20 mA with HART protocol
Alarm Events: Alarm on over-range
Alarm Types: Digital and Analog (configurable)
Analog Alarm Options: Current high (22.5 mA) with auto-reset (default), current high with manual reset, or none
Output Damping: 0, 1, 2, 5, 10, 20, 50 s
Load: Minimum load for HART communication: 250 O

Certificates and Approvals

Ex Approval: LCIE 05 ATEX 6097X , for additional certificates contact Metal Samples
CSA Approval: cCSAus certified for USA and Canada; Certificate no. 1563164
IS: Cl. I, II, III; Div. 1, 2; Groups A-G
EX: Cl. I; Div. 1, 2; Groups A-D
NI: Cl. I, II, III; Div. 2; Groups A-G
Type of Protection: II 1G EEx ia IIC T4
Patents: U.S. patents: 7,239,156; 7,245,132; 7,265,559; 7,282,928

Conformity Information

Directive 94/9/EC (ATEX): EN 50014, EN 50020, EN 50284
Degree of Protection: EN 60529

EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information contact Metal Samples.

MS2900L - CorrTran MV
User Manual

METEX CORPORATION LIMITED

About Us

Metex Corporation Limited has been providing superior products and services to the process control, chemical treatment, waste water, industrial and manufacturing industries for over 25 years. It is our goal to continually provide our customers with the best possible equipment, technology, and service.

Sitemap

Our Products

Dataloggers, sensors, pumps, recorders, hand held instruments, flow instrumentation, level controls, valves, instrumentation, containers, tanks, transmitters, data loggers, digital indicators, mixers and agitators, pressure intrumentation, analyzers and controllers for a variety of industrial applications such as water quality, pH/ORP and more.

Website Content

Water Analyzers and Controllers, Wireless Products, Corrosion Monitoring Equipment, Cooling Tower and Boiler Controllers, a wide variety of Pumps, Valves, Dataloggers and Recorders, HVAC, Instrumentation, Skids and Systems, Containers and Tanks from world leading manufacturers are products you will find on this site.