Search This Site

(Search by Product Type i.e. Level or Brand Name i.e. Walchem)

PD603 Sabre P Low-Cost Process Digital Panel Meter



The Sabre P PD603 process meter combines operational simplicity with high end features to deliver the perfect low-cost 1/8 DIN digital panel meter for display only applications. The PD603’s menu structure is easy to navigate because the only selections are for input, decimal point location, and scaling values; there are no other menu choices to add confusion during the setup process. Despite being a low-cost meter, the PD603 is still packed with many features typically found only on more expensive meters, such as a NEMA 4X front, universal power supply, front panel programming, input current overload protection, UL listing, and CE marking.

Features

  • 0-20, 4-20 mA, 0-5, 1-5, 0-10, ±10 V Inputs
  • Input Current Overload Protection
  • NEMA 4X, IP65 Front
  • Shallow Depth 1/8 DIN Case 3.6" Behind Panel
  • 4 Digit Display, 0.56” (14 mm) High, Red LEDs
  • Easy Front Panel Programming
  • Scale without a Signal Source
  • Calibrate with a Signal Source
  • Maximum/Minimum Display
  • Universal Power Supply 85-265 VAC
  • 12-36 VDC/12-24 VAC Power Option
  • 24 VDC @ 200 mA Transmitter Supply Option

PD6100 ProVu Strain Gauge, Load Cell & mV Digital Panel Meter Data Sheet
PD6100 ProVu Strain Gauge, Load Cell & mV Digital Panel Meter Instruction Manual

General Specifications

  • Display: Upper display: 0.60" (15 mm) high. Lower display: 0.46" (12 mm) high. Both are 6 digits (-99999 to 999999), red LEDs.
  • Display Intensity: Eight intensity levels
  • Display Update Rate: 5/second (200 ms)
  • Overrange: Display flashes 999999
  • Underrange: Display flashes -99999
  • Display Assignment: The displays may be assigned to PV1, PV2, PCT, max & min, set points, PV & units, units (lower display only), net & gross weight, Modbus input, and display millivolts.
  • Units: lb, kg, ounce, gram, ton, metric ton (tonne), custom units.
  • Front Panel: NEMA 4X, IP65
  • Programming Methods: Four front panel buttons, digital inputs, PC and MeterView Pro software, Modbus registers
  • F4 Digital Input Contacts: 3.3 VDC on contact. Connect normally open contacts across F4 to COM.
  • F4 Digital Input Logic Levels: Logic High: 3 to 5 VDC
  • Logic Low: 0 to 1.25 VDC
  • Noise filter: Programmable from 2 to 199 (0 will disable filter)
  • Filter Bypass: Programmable from 0.1 to 99.9% of calibrated span
  • Rounding: Select 1, 2, 5, 10, 20, 50, or 100 (e.g. rounding = 10, value = 123.45, display = 123.50).
  • Recalibration: All ranges are calibrated at the factory. Recalibration is recommended at least every 12 months.
  • Max/Min Display: Max/min readings reached by the process are stored until reset by the user or until power to the meter is cycled.
  • Password: Three programmable passwords restrict modification of programmed settings.
  • Non-Volatile Memory: All programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost.
  • Power Options: 85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max, or
    optional model with 12-24 VDC ±10%, 15 W max.
  • Fuse: Required external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse.
  • Isolated Sensor Power Supply:
  • Terminals Ex+ & Ex-: 10 VDC or 5 VDC ± 10%. Rated @ 350 mA max.
    Note: Do not use 24 VDC to power strain gauge bridge
  • Normal Mode Rejection: Greater than 60 dB at 50/60 Hz
  • Isolation: 4 kV input/output-to-power line. 500 V input-to-output (powered by external supply).
  • Overvoltage Category: Installation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.
  • Environmental: Operating temperature range: -40 to 65°C
  • Storage temperature range: -40 to 85°C
  • Relative humidity: 0 to 90% non-condensing
  • Connections: Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adapters.
  • Enclosure: 1/8 DIN, high impact plastic, UL 94V-0, color: black
  • Mounting: 1/8 DIN panel cutout required: 3.622" x 1.772"
    (92 mm x 45 mm). Two panel mounting bracket assemblies are provided.
  • Tightening Torque: Screw terminal connectors: 5 lb-in (0.56 Nm)
  • Dimensions: 4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm) (W x H x D)
  • Weight: 9.5 oz (269 g)
  • UL File Number: UL & c-UL Listed. E160849; 508 Industrial Control Equipment.
  • Warranty: 3 years parts & labor
  • USB Connection: Compatibility: USB 2.0 Standard, Compliant Connector Type: Micro-B receptacle
  • Cable: USB A Male to Micro-B Cable
  • Driver: Windows 98/SE, ME, 2000, Server 2003/2008, XP 32/64-Bit, Vista 32/64-Bit, Windows 7 32/64-Bit, Windows 10 32/64-Bit
  • Power: USB Port

Strain Gauge Input

  • Inputs: Field selectable: 0-15, 0-30, 0-150, 0-300 mV, ±15, ±25, ±150, ±250 mV, or Modbus PV (Slave)
  • Accuracy: ±0.03% of calibrated span ±1 count
  • Minimum Load Resistance: 28 O @ 5 V or 10 V
  • Maximum Excitation Current: 350 mA @ 5 V or 10 V
  • Temperature Drift: 0.002% of calibrated span/°C max from 0 to 65°C ambient, 0.005% of calibrated span/°C max from -30 to 0°C ambient
  • Function: Linear with multi-point linearization
  • Low-Flow Cutoff: 0-999999 (0 disables cutoff function)
  • Decimal Point: Up to five decimal places or none: d.ddddd, dd.dddd, ddd.ddd, dddd.dd, ddddd.d, or dddddd.

Relays

  • Rating: 2 or 4 SPDT (Form C) internal and/or 4 SPST (Form A) external; rated 3 A @ 30 VDC and 125/250 VAC resistive load; 1/14 HP (˜ 50 watts) @ 125/250 VAC for inductive loads such as contactors, solenoids, etc.
  • Noise Suppression: Noise suppression is recommended for each relay contact switching inductive loads.
  • Deadband: 0-100% of span, user programmable
  • High or Low Alarm: User may program any alarm for high or low trip point. Unused alarm LEDs and relays may be disabled (turned off).
  • Relay Operation: Automatic (non-latching), latching (requires manual acknowledge), sampling (based on time), pump alternation control (2 to 8 relays), Off (disable unused relays and enable interlock feature, manual on/off control mode).
  • Relay Reset: User selectable via front panel buttons or digital inputs.
    1. Automatic reset only (non-latching), when input passes the reset point.
    2. Automatic + manual reset at any time (non-latching).
    3. Manual reset only, at any time (latching).
    4. Manual reset only after alarm condition has cleared (latching).
    Note: Front panel button or digital input may be assigned to acknowledge relays programmed for manual reset.
  • Time Delay: 0 to 999.9 seconds, on & off relay time delays. Programmable and independent for each relay.
  • Fail-Safe Operation: Programmable and independent for each relay.
    Note: Relay coil is energized in non-alarm condition. In case of power failure, relay will go to alarm state.
  • Auto Initialization: When power is applied to the meter, relays will reflect the state of the input to the meter.

Serial Communications

  • Protocol: Modbus® RTU (Slave Only)
  • Meter Address/Slave ID: 1 - 247
  • Baud Rate: 300 - 19,200 bps
  • Transmit Time Delay: Programmable between 0 and 199 ms or transmitter always on for RS-422 communication
  • Data: 8 bit (1 start bit, 1 or 2 stop bits)
  • Parity: Even, odd, or none with 1 or 2 stop bits
  • Byte-to-Byte Timeout: 0.01 - 2.54 seconds
  • Turn Around Delay: Less than 2 ms (fixed)
    Note: Refer to the ProVu Modbus Register Tables for details

Isolated 4-20 mA Transmitter Output

  • Output Source: Process variable (PV), max, min, set points 1-8, manual control setting, or Modbus input
  • Scaling Range: 1.000 to 23.000 mA for any display range
  • Calibration: Factory calibrated: 4.000 to 20.000 = 4-20 mA output
  • Analog Output Programming: 23.000 mA maximum for all parameters:
  • Overrange, underrange, max, min, and break
  • Accuracy: ± 0.1% of span ± 0.004 mA
  • Temperature Drift: 0.4 µA/°C max from 0 to 65°C ambient, 0.8 µA/°C max from -40 to 0°C ambient
    Note: Analog output drift is separate from input drift.
  • Isolated Transmitter Power Supply: Terminals I+ & R: 24 VDC ± 10%. Isolated from the input at >500 V. May be used to power the 4-20 mA output or other devices. All models rated @ 40 mA max.

Digital I/O Expansion Module

  • Channels: 4 digital inputs & 4 digital outputs per module
  • System: Up to 2 modules for a total of 8 inputs & 8 outputs
  • Digital Input Logic: High: 3 to 5 VDC
  • Low: 0 to 1.25 VDC
  • Digital Output Logic: High: 3.1 to 3.3 VDC
  • Low: 0 to 0.4 VDC
  • Source Current: 10 mA maximum
  • Sink Current: 1.5 mA minimum
  • +5 V Terminal: To be used as pull-up for digital inputs only

4-Relay Expansion Module

  • Relays: (4) Form A (SPST) rated 3 A @ 30 VDC and 125/250 VAC resistive load; 1/14 HP (approx. 50 watts) @ 125/250 VAC for inductive loads

METEX CORPORATION LIMITED

About Us

Metex Corporation Limited has been providing superior products and services to the process control, chemical treatment, waste water, industrial and manufacturing industries for over 25 years. It is our goal to continually provide our customers with the best possible equipment, technology, and service.

Sitemap

Our Products

Dataloggers, sensors, pumps, recorders, hand held instruments, flow instrumentation, level controls, valves, instrumentation, containers, tanks, transmitters, data loggers, digital indicators, mixers and agitators, pressure intrumentation, analyzers and controllers for a variety of industrial applications such as water quality, pH/ORP and more.

Website Content

Water Analyzers and Controllers, Wireless Products, Corrosion Monitoring Equipment, Cooling Tower and Boiler Controllers, a wide variety of Pumps, Valves, Dataloggers and Recorders, HVAC, Instrumentation, Skids and Systems, Containers and Tanks from world leading manufacturers are products you will find on this site.

Get in Touch