The Survivor PD662 NEMA 4X, CSA Certified (Electric Safety), loop-powered meter is perfect for applications where a simple, inexpensive display is required and AC power is not available; the meter derives all its power from the 4-20 mA loop. The meter is scaled using four push buttons and can be done without applying a calibration signal. It features a 3½ digit 0.6" display that will read up to 2999. The loop-powered backlight option lets you see the display under any lighting condition and is powered completely from the 4-20 mA loop. The optional DC-powered heater allows the PD662 to operate in temperatures as low as -55°C.

Features

  • 4-20 mA Input
  • 3½+ Digit 0.6" Display
  • Easy Four-Button Programming
  • NEMA 4X Enclosure
  • Programmable Noise Filter
  • Loop-Powered Backlight Option
  • Max/Min Display
  • HART Protocol Transparent
  • 1.7 V Drop without Backlight
  • CSA Certified for -40 to 75°C Operation
    (-55 to 75°C with Heater Option)

PD662 Survivor NEMA 4X Loop-Powered Process Meter Data Sheet
PD662 Survivor NEMA 4X Loop-Powered Process Meter Instruction Manual

General Specifications

  • Display: 0.6" (15.24 mm) LCD, 3½+ digits; -1999 to 2999
  • Display Update Rate: 2 Updates/Second
  • Over-Range: Display Flashes 2999
  • Under-Range: Display Flashes -1999
  • Programming Method: 4 Front Panel Pushbuttons
  • Noise Filter: Programmable HI, LOW, or OFF
  • Recalibration: Recalibration is recommended at least every 12 months.
  • Max/Min Display: Max/Min readings reached by the process are stored until reset by the user or until power to the meter is turned off.
  • Non-Volatile Memory: All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost.
  • Normal Mode Rejection: 64 dB at 50/60 Hz
  • Environmental: Operating Temperature for CSA Certification: -40 to 75°C.
  • Functional Temperature Range: -40 to 85°C. Storage Temp.: -40 to 85°C.
  • Relative Humidity: 0 to 90% non-condensing.
  • Connections: Removable screw terminals accept 12 to 22 AWG
  • Tightening Torque: Screw terminal connectors: 4.5 lb-in (0.5 Nm)
  • Enclosure: Impact-resistant polyester plastic, body color gray, clear cover with blue faceplate; NEMA 4X, IP66; ½" conduit hole provided at base
  • Weight: 9.3 oz (264 g)
  • Overall Dimensions: 3.15" x 4.33" x 2.76" (80 mm x 110 mm x 70 mm) (W x H x D)
  • Warranty: 3 years parts & labor

Input

  • Input: 4-20 mA
  • Accuracy: ±1 count
  • Temperature Drift: 50 PPM/°C from -40 to 85°C ambient
  • Decimal Point: User selectable decimal point
  • Minimum Span: Input 1 & Input 2: 0.40 mA
  • Maximum Voltage Drop: 1.7 VDC @ 20 mA; 4.9 VDC @ 20 mA with backlight option.
  • Equivalent Resistance: 85 O @ 20 mA without backlight; 185 O @ 20 mA with backlight
  • Loop-Powered Backlight Option: Factory installed only with field wiring option. Powered directly from the 4-20 mA loop, no batteries required. The display brightness will increase as the input signal current increases.
  • HART Transparency: Analog input will not interfere with existing HART communications on the wired 4-20 mA signal

Heater Option

  • Power: 24 VDC, 11 W Maximum.
  • Required Switch & Fuse: A CSA Approved fuse rated min 30 VDC, 1 A, T and a readily accessible switch or a circuit breaker shall be provided to facilitate the disconnection of power to the heater.
  • Environmental: Operating Temperature for CSA Certification: -55 to 75°C.
  • Functional Operation: -55 to 85°C. Storage Temperature: -55 to 85°C.
  • Relative Humidity: 0 to 90% non-condensing.
  • Temperature Cutoff: Internal 104°C thermal cutoff for over temperature protection.

CSA Certification

  • CSA Certified: U.S. & Canada. 2252 05 — Process Control Equipment. 2252 85 — Process Control Equipment, U.S. Standards.
  • CSA File Number: 157123
  • CSA Applicable Requirements: CAN/CSA C22.2 No. 61010-1-04 Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use – Part 1: General
  • Requirements UL 61010-1:2004, 2nd Edition Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use – Part 1: General Requirements.

METEX CORPORATION LIMITED

About Us

Metex Corporation Limited has been providing superior products and services to the process control, chemical treatment, waste water, industrial and manufacturing industries for over 25 years. It is our goal to continually provide our customers with the best possible equipment, technology, and service.

Sitemap

Our Products

Dataloggers, sensors, pumps, recorders, hand held instruments, flow instrumentation, level controls, valves, instrumentation, containers, tanks, transmitters, data loggers, digital indicators, mixers and agitators, pressure intrumentation, analyzers and controllers for a variety of industrial applications such as water quality, pH/ORP and more.

Website Content

Water Analyzers and Controllers, Wireless Products, Corrosion Monitoring Equipment, Cooling Tower and Boiler Controllers, a wide variety of Pumps, Valves, Dataloggers and Recorders, HVAC, Instrumentation, Skids and Systems, Containers and Tanks from world leading manufacturers are products you will find on this site.

Get in Touch