PD900 Consolidator Multi-Channel Controller

USA Toll Free: 1-800-730-0302 Tel: 416-240-1920 - sales@metexcorporation.com



The ConsoliDator® PD900 is an easy-to-use, multi-channel controller that accepts up to eight (8) 4-20 mA inputs, four (4) flowmeter pulse inputs, and up to eight (8) digital inputs, then displays them on a large, backlit, graphical LCD screen. It is available in four models: the PD940 (4 input, wall mount), the PD941 (4 input, panel mount), PD980 (8 input, wall mount), and the PD981 (8 input, panel mount). While programming the meter, onscreen soft keys appropriately and clearly relabel the action of the front panel buttons making menu navigation quick and simple. In operating mode, the ConsoliDator’s main screen displays all the inputs in both numeric and bar graph format and its individual screens display detailed information about each. The ConsoliDator is suitable for all safe area monitoring and controlling applications such as flow, level, pressure, temperature, and vibration. The availability of Modbus® RTU serial communications makes it ideal for SCADA applications.

Features

  • Easy to Read Backlit LCD
  • Readable in Direct Sunlight
  • Bargraphs & Numeric Screens
  • Easy to Set up & Configure
  • Set up with Front Panel Keys
  • Intuitive Menus
  • Detailed Individual Screens
  • Input Simulation Feature
  • RS-232 Modbus RTU
  • Direct Modbus PV Inputs
  • Power from AC or DC
  • Wall or Panel Mount
  • 32-Point Linearization
  • Sum & Difference Functions
  • Free Programming & Data Logging Software
  • A Good Match for Wireless
  • Four Pulse Inputs
  • Four Digital Inputs
  • Nine 10 A Relays
  • Process/Rate & Total Display

PD900 Consolidator Multi-Channel Controller Data Sheet

PD900 Consolidator Multi-Channel Controller Instruction Manual

General Specifications

  • Display Update Rate: 2 seconds
  • Programming Method: Front panel buttons, external buttons, PC with ConsoliDator software, or Modbus registers.
  • Password: Programmable, restricts modification of settings.
  • Non-Volatile Memory: Settings stored for a minimum of 10 years.
  • Power: 90-264 VAC, 47-63 Hz, 20 VA or 8-30 VDC, 15 W (field)
  • Isolation: AC: 1500 V; signal and output power grounds are connected to earth ground (chassis); DC: not isolated.
  • Surge Protection: Analog inputs have chokes & TVS
  • Operating Temperature: 0 to 50°C
  • Relative Humidity: 0 to 90% non-condensing
  • Storage Temperature: -40 to 60°C
  • Connections: Removable screw terminals and DB9 male
  • Enclosure: NEMA 1, powder-coated steel; color: warm gray
  • Mounting: Panel or wall mount models
  • Weight: 5.5 lb (2.5 kg)
  • Warranty: 1 year parts & labor

Screen Didplays

  • Numeric Display: Six digits, ±999999 or 99' 11.9" (feet & inches)
  • Bargraph: Twenty divisions
  • Engineering Units: User selectable or definable units (e.g. ppm, gal, m, lb, g/h, psi, ozs, ft, mA, ºC, ºF, f & i, %)
  • Master Input Screen:
  • Numeric Displays: Eight; process value & engineering units
  • Bargraphs: Eight; process & channel number
  • Individual Input Screen:
  • Numeric Displays: Process and mA input value
  • Bargraphs: High and low set point markings
  • Simulation Mode: Test setup without applying an input

Analog Inputs

  • Number of Inputs: Four (ConsoliDator 4); Eight (ConsoliDator 8)
  • Input: 4-20 mA; minimum span of 1 mA
  • Accuracy: ±0.03% FS ±1 count
  • Input Function: Linear, square root, programmable exponent, or fixed value
  • Programmable Exponent: From 0.50001 to 2.99999
  • Multi-Point Linearization: 2 to 32 points, accessible through ConsoliDator software or Modbus registers.
  • Math Function: Sum or difference of 2 or more channels
  • Totalizer: Calculates total based on rate and time base of seconds, minutes, hours, or days; stored in non-volatile memory every 5 minutes; supports linear inputs only.
  • Totalizer Reset: Via front panel buttons (password restricted)
  • Input Impedance: 130 O
  • HART Transparency: Analog input will not interfere with existing HART communications on the wired 4-20 mA signal
  • Transmitter Supply: 24 VDC @ 20 mA per input; short circuit protection: current limited to 40 mA max per input

Pulse Inputs

  • Number of Inputs: Four
  • Input: 100 mVp-p to 15 Vp-p; 1 Hz to 10 kHz
  • Accuracy: ±1 count for K-Factor >1
  • K-Factor: 0.00001 to 999999 pulses/unit
  • Totalizer: Calculates total based on rate, stored in non-volatile memory every 5 minutes.
  • Totalizer Reset: Via front panel buttons (password restricted)

Dual Process Input

  • Number: Up to 4 (ConsoliDator 4), and up to 8 (ConsoliDator 8)
    Input: Modbus via RS-232 serial port

Modbus PV Inputs

  • Number: Up to 4 (ConsoliDator 4), and up to 8 (ConsoliDator 8)
  • Input: Modbus via RS-232 serial port

Relays

  • Number of Relays: Nine
  • Relay Type: Form C (SPDT) with built in MOVs
  • Rating: 10 A @ 120/240 VAC resistive load; 1/3 HP @ 120/240 VAC inductive loads; 5 A @ 28 VDC
  • Minimum Load: 50 mA for AC, 10 mA @ 5 VDC
  • Assignment: Any relay may be assigned to any channel. Multiple relays may be assigned to one channel. All relays are programmed independently.
  • Cycle Monitoring: Controller tracks time relay has been active and number of times relay has cycled on/off.
  • Time Delay: Programmable on/off delays, 0 to 999.9 seconds
  • Operation: (see instruction manual for complete list) High or Low Alarm, Multi-Channel Alarm, Summary Alarm, Supervisory Alarm, and Lead-Lag Alternation (Sequence)
  • Manual Override: Override any relay (password restricted). Relays do not respond to input while in this mode.

4-20 mA Analog Output

  • Number: Four (ConsoliDator 4); Two (ConsoliDator 8) Assign to any process or pulse input
  • Accuracy: ±0.05% FS ±0.01 mA
  • Mode: Linear or manual tuning PID
  • Loop Resistance: 10 to 600 O, powered by controller
  • External Loop Power Supply: 12 VDC min (300 O max); 32 VDC max (900 O max)
  • Isolation: 1500 V output-to-power line; 500 V output-to-input when powered by external supply.

Modbus Communications

  • Compatibility: EIA-232
  • Protocol: Modbus RTU
  • Address: Programmable between 1 and 247
  • Baud Rate: 1,200 to 38,400 bps
  • Transmit Delay: Programmable between 0 and 300 ms
  • Data: 8 bits (1 start bit, 1 stop bit)
  • Parity: Even, None with 1 stop bit, or None with 2 stop bits

ConsoliDator Software

  • System Requirements: Windows® 95/98/ME/NT4/2000/XP/Vista/7/8
  • Communications: RS-232 using null-modem serial cable
  • Compatibility: ConsoliDator 4 & ConsoliDator 8, two versions
  • Configuration: Configure inputs and outputs. Save settings to file for programming other controllers or restoring settings.
  • Logging Interval: 1 second to 10 minutes
  • Data Logging Report: Log to comma separated value(.csv) file compatible with spreadsheet applications

METEX CORPORATION LIMITED

About Us

Metex Corporation Limited has been providing superior products and services to the process control, chemical treatment, waste water, industrial and manufacturing industries for over 25 years. It is our goal to continually provide our customers with the best possible equipment, technology, and service.

Sitemap

Our Products

Dataloggers, sensors, pumps, recorders, hand held instruments, flow instrumentation, level controls, valves, instrumentation, containers, tanks, transmitters, data loggers, digital indicators, mixers and agitators, pressure intrumentation, analyzers and controllers for a variety of industrial applications such as water quality, pH/ORP and more.

Website Content

Water Analyzers and Controllers, Wireless Products, Corrosion Monitoring Equipment, Cooling Tower and Boiler Controllers, a wide variety of Pumps, Valves, Dataloggers and Recorders, HVAC, Instrumentation, Skids and Systems, Containers and Tanks from world leading manufacturers are products you will find on this site.

Get in Touch