Model 2450 Reverse Osmosis Monitor
from Lakewood Instruments
USA Toll Free: 1-800-730-0302 Tel: 416-240-1920 - sales@metexcorporation.com
Model 2450 Reverse Osmosis Monitor
The Model 2450 uses LonWorks� Technology which is the latest in microprocessor capability that gives the user the highest level of application flexibility.
A large illuminated graphics screen, multiple inputs and very easy setup with easy field upgrades characterize this new technology.
Water meters and sensors are purchased separately.
Features
-
Uses 2-electrode conductivity sensor with � inch MNPT process connection.
-
Uses differential pH sensor with � inch MNPT process connection.
-
Two watermeter inputs for Permeate and Concentrate flow rates.
-
RS232 output for remote monitoring, control and data acquisition (-RS2L).
-
4-20 mA output for (-35L, select any four):
pH, conductivity, temperature
concentrate flow,
permeate flow,
percent recovery.
-
-
-
Five (5) Count down timers
Lubrication interval
Check CIP
Check filters
Check sepralators
Check sensor
-
Four (4) relays have user-selectable options:
pH setpoint;
conductivity setpoint;
temperature setpoint
permeate flow setpoint;
concentrate flow setpoint;
percent recovery setpoint;
various alarms.
LonWorks is a registered trademark of Echelon Corporation.
Specifications
Inputs
|
|
Power
|
80-300 VAC
|
Sensor
|
2 or 4-electrode Conductivity pH differential
|
Temperature Comp.
|
None, 500 NTC, 4K NTC
|
CIP Switch
|
Dry contact
|
Water Meter Inputs
|
Two, open collector type
|
Outputs
|
|
Relays
|
3 Amps @ 120 VAC
|
4-20 mA
|
Two, isolated w/-35L
|
RS232
|
Requires Windows-based PC w/-RTC-RS2L
|
Monitor
|
|
pH Range
|
0-14 pH
|
pH Accuracy
|
+/- 0.05 pH
|
pH Resolution
|
0.01 pH
|
Conductivity Range
|
0-100 or 0-1000 µS (with proper sensor)
|
Conductivity Accuracy
|
+/-1 or +/-10 µS (with proper sensor)
|
Conductivity Resolution
|
1 or 10 µS (with proper sensor)
|
Deadband
|
Adjustable
|
Setpoints
|
Direct or Reverse (configurable in the field)
|
Keypad
|
Numeric
|
Display
|
Illuminated 128x64 pixel LCD
|
Ambient Temperature
|
32-158ºF (0-70ºC)
|
Enclosure
|
ABS Plastic
|
Options

2450
|
LonWorks Technology-based Reverse Osmosis Monitor including the Real Time Clock
|
|
(-RTC) option. Sensors and water meters ordered separately.
|
CONTROLLER OPTIONS
(optional; select no more than two, two -35L may be purchased)
|
-35L
|
Two 4-20 mA outputs (two -35L cards may be used for up to 4 outputs).
|
-RS2L
|
Communications node with the LRWS program
|
SENSOR OPTIONS
|
1104593
|
pH High Purity sensor, 1/4 inch NPT flow cell
|
520-4-7I-10-STD
|
pH sensor 0-14 pH, 3/4 inch NPT
|
540K0.1-4-10I-10-TC 500
|
Conductivity Sensor 0-10 µS, 3/4 inch NPT
|
540K.1-4-10I-10-TC 500
|
Conductivity Sensor 0-100 µS, 3/4 inch NPT
|
543-L-4-8I-10-STD
|
Conductivity Sensor 0-1000 µS, 1 inch NPT
|
543-M-4-8I-10-STD
|
Conductivity Sensor 500-100,000 µS, 1 inch NPT
|
AUTOTROL TURBINE WATER METER OPTIONS
|
1TM-NPT
|
1 inch turbine water meter with brass pipe thread adapters
|
1TM-ESW
|
1 inch turbine water meter with PVC solvent weld adapters
|
2TM-NPT
|
2 inch turbine water meter with brass pipe thread adapters
|
2TM-ESW
|
2 inch turbine water meter with PVC solvent weld adapters
|
49C25
|
25 ft cable for turbine meters
|
49C50
|
50 ft cable for turbine meters
|
SOFTWARE AND EXTERNAL MODEM OPTIONS
|
LRWS
|
Windows-based registered software for computer to communicate with 2000 Series Controllers.
|
MD4X
|
High-Baud modem in NEMA-4 enclosure ready to power
|
MD
|
High-Baud modem for use with 2000 Series Controllers
|
Model 2450 Cut Sheet
Model 2450 Spec Sheet
Model 2450 Manual
|